i-on160 Introduction
Page 3
External Bell Output
The control unit has one external bell output to drive standard Self-Activating
Bell (SAB) or Self-Contained Bell (SCB) modules. Expanders also provide
connectors for additional external sounders. See i-on160EX Installation Guide
for details of maximum current available for external bells.
Extension Loudspeaker Connectors
If required the Installer can connect one 16Ohm extension loudspeaker to
increase the audibility of setting and unsetting tones. Each expander also
provides connectors for a 16Ohm extension loudspeakers. Note that you must
not connect another loudspeaker in parallel to these connectors.
Battery Backup
As noted above, the case provides space for two 17Ah backup batteries. Each
battery has its own connector on the control unit pcb, and is charged by the
control unit while mains power is present.
It is possible to run the system with a single backup battery (although the
resulting standby time may not meet the Grade 2 or Grade 3 requirements). If
you chose to use a single battery, then you should connect the battery to
connector “BATT1” and program the control unit to suppress alerts that Battery
2 is missing, see page 72.
Keypads
The i-on160EX uses i-kp01 keypads with keypad firmware version 2.0 and
above. The keypad has a two line by 20 character backlit LCD display and a
built in proximity tag (prox tag) reader. All keypads connect directly to the
system bus.
Users can set and unset the system or partitions from the keypad, either by
keying-in access codes or presenting a prox tag.
Provided that they are in separate partitions, the control unit can process up to
five keypads in use at the same time. Within a partition, the control unit
responds to just one keypad at a time. In a part setting system (one not using
partitions) the control unit responds to just one keypad at a time.
The Installer can also program the system from the keypad.
Expanders
Wired Expander The EXP-W10 wired expander provides connections for:
Either 10 FSL zones or five CCL zones.
One loudspeaker
Four wired programmable outputs
Radio Expander The radio expanders provide channels for either 10 radio
detectors (EXP-R10) or 30 radio detectors (EXP-R30). In
addition each radio expander provides channels for: two
radio keypads, two external radio sounders and two Wireless
Accessory Modules (WAMs). Each radio expander also
provides wired connections for a Loudspeaker.
Note: The total number of radio detectors that can be