Installer Menu Options i-on160
Page 36
Use this zone type to monitor the fault output of an external PSU. (This
zone type is available for power supplies that do not provide specific fault
outputs that can be used by zone types 11, 12 and 13.) If a power supply
triggers a zone with this type then the control unit activates any output
programmed as “External PSU Fault” and causes an alert that displays
“External power fault” on the keypad.
If the alarm system is set then the control unit logs the event, starts any
programmed communication, but does not start an alarm.
Note: Zone type 15 is not used.
Log Only (16)
When a detector triggers a zone with this type the control unit logs the
event and activates any outputs that are programmed to follow this zone.
The zone is active whether the system is set or unset. Typical uses for this
zone type are for integrating the alarm system with a CCTV system.
Note: Zone Follow outputs will activate on both Alarm and Tamper of a Log
Only zone.
Partitions
Note: This menu does not appear if a zone has the type “Not Used”.
In a partitioned system you can assign zones to any of the partitions. Any zone
can belong to one or more partitions.
Note: If you assign a zone to more than one partition then that zone will only
be set when all the partitions it belongs to are set.
When delivered from the factory, or if you restore the control unit to factory
settings, then all zones belong to partition 1.
Once you have entered the Partitions option, press u or n to scroll through
the list of partitions followed by > or < to allocate/deallocate the zone to each
partition as necessary.
If you wish to allocate/deallocate the zones to many partitions you can use the
“All Partitions” option (in between partition 1 and 20 on the menu) to either
allocate or deallocate the zone to all partitions in one operation. Once you have
carried out this operation you can then scroll through the partition list and
change the allocation of zones as necessary.
Zone Attributes
Note: This menu does not appear if a zone has the type “Not Used”.
You can assign more than one attribute to a zone. Some attributes are not
available for certain zone types. The display shows only the available attributes
for the zone type you select.
To enable an attribute for a zone press > or < until the bottom line of the
display shows “Yes” at the right hand end.