i-on160 Step by Step Programming Procedures
Page 111
the control unit successfully learns the detector.
9. Either: Press
X to go back to the list of zones
so that you can go on and learn other detectors.
The control unit stores the identity of the radio
detector, but sets the type to “Not Used”.
ADD/DEL DETECTORS
*Zone 021
OR: Press Y to carry on
g
ivin
g
a name, type and
attribute to the detector you have just learned
(see page 33 ).
The control unit give the detector a zone type
“Normal Alarm” and assigns it to Partition 1.
10. Carry on with any other programming that you
need to do. DON’T FORGET to leave the Installer
Menu in order to save the changes you have
made (see page 7 ).
Deleting individual radio detectors
1. Enter Installer Menu.
INSTALLER MENU
Detectors/Devices >
2. Press Y.
DETECTORS/DEVICES
Detectors >
3. Press Y .
DETECTORS
Add/Del Detectors >
4. Press Y .
The bottom line of the display shows the first of
the radio expanders.
ADD/DEL DETECTORS
Exp. R1-02 (R10)>
5. Press u or n to show the expander you want
and press Y.
The bottom line of the display shows the first of
the radio detector zones belonging to the
selected expander.
The display shows an “*” next to zones where
the control unit has already learned detectors.
ADD/DEL DETECTORS
*Zone 020 >
Zobrazit stránku 116