4. Programming
496964 Page 87
76: Level/Partition D Exit Mode
This Command sets the Exit Mode for Level or Partition D.
In a single system, the options are:
Option
0 The keypad sounders and any internal sounders give a low tone
during exit of Level D. Use Command 79 to select the exit time.
1 Instant Set (no exit tone)
2 Silent Set. Use Command 79 to program the Exit time. At the end of
the exit time the keypad gives a double "beep" confirmation tone.
3 Makes the Level D exit mode the same as Level A.
In a partitioned system, the options are:
Option
0 Timed. Use this option if Partition D sets after an exit time selected
using Command 79. If an Exit Terminate button is fitted, the user may
use it to shorten the exit time.
1 Terminate. Use this option if the user completes setting the partition
by pushing an Exit Terminate button connected to a keypad. The exit
time is infinite in this option.
2 Final Door Set. Use this option to complete setting the partition by
closing a door fitted with a Final Exit zone detector. The exit time is
infinite in this option.
3 Instant Set (no exit tone)
4 Silent Set. Use Command 79 to program the Exit time. At the end of
the exit time the keypad gives a double "beep" confirmation tone.
5 Lock Set. See "Level A Exit Mode (Command 39) for an explanation
of Lock Set.
Note: The keypads give a double "beep" confirmation tone at the end of all
setting modes.