3. Installation
496964 Page 33
Note: Make sure that the control unit and the expander use the same wiring
method for zones. If you select a different wiring method for zones on the
expander, the control unit may not report tampers correctly.
FSL
EOL
Four-wire CC
Two-wire FSL
Two-wire EOL
Figure 24. Link Positions to Select Wiring Method
Once you have connected an expander, refer to the instructions supplied with
it for connecting hardwired detectors or "learning" radio detectors as
appropriate.
Addressing Expanders
If you fit expanders, you must allocate each expander to a specific range of
zone numbers. Do not allocate two expanders to the same range of zones.
Select the zone numbers by fitting a jumper link to one pair of the set of pins
marked "Address" on the expander PCB, as shown in Figure 25.
2
3
4
2
3
4
2
3
4
Zones 9 to 16
Zones 17 to 24
Zones 25 to 32
Zones 33 to 40.
2
3
4
Figure 25. Link Positions to Allocate Expanders to Zones
Notes:
1. The first option is not available if the control unit is providing zones 1
to 16 (only possible with 9851 control units).
2. The third position is not available for 9751 control units.
3. The fourth position is not available for 9751 or 9752 control units.