Programming i-on16
Page 50
Reset System reset 305
Exit timeout Exit timeout and restore 457
Omit Zone omit 573
RF supervision Zone supervision fail and restore
Radio keypad supervision fail and restore
External siren supervision, fail and restore
381
RF jamming Jamming fail and restore 344
Smoke power supply unit fail and restore 337
Zone low battery fail and restore 384
RF battery psu
Ext Siren low battery fail and restore 338
End station low battery and restore 302 Panel battery
End station battery missing and restore 311
Mains Fail Mains fail and restore 301
Smoke fault and restore 373 Faults
Comms line fault and restore 351
Installer mode start 627 Installer mode
Installer mode end 628
Time date reset Time and date reset 625
Restorals
When you enable a CID Report Group, the control unit
sends the relevant telegram both when an event occurs,
and when the condition causing the event stops. The
second transmission of the telegram is also called a
“restore”.
You can enable or disable restoral reporting by selecting
Reporting – Alarms – Restorals. The options available are:
Disabled
Restore off. The control unit does not communicate
restores.
Enabled.
Restore on. The control unit does communicate
restores.
Burg Comms Rearm
This menu option determines what the control unit does
with the “Burg” Fast Format channel 3 at the end of the
siren run time. There are two options:
Disabled
The channel stays active until an Installer or user
resets the system.