i-on16 Technical Specification
Page 7
Power Supply
This product complies with the requirements of EN50131-
6 Type A power supply at Grade 2 and environmental
class 2.
Mains power supply 230VAC +10%/-15%, 170mA
max, 50Hz.
End station psu 13.7VDC, 1.5A max
End station consumption 145mA.
Communicator consumption 50mA max
Keypad consumption 30mA (backlight off)
45mA (backlight on)
65mA (backlight on max)
Standby Battery 12V, 7Ah sealed lead acid.
Standby time: more than 12
hours.
Max recharge time: less than
72 hours.
Battery charge limit 270mA
12V Aux supply (inc LS) 13.7VDC +0.1/-0.4 @ 850mA
max.
14V4 supply 14.4V +0.1/-0.2 @ 230mA
12V Keypad bus 13.7V =0.1/-0.5 @ 400mA
max
Monitoring includes Mains fail, battery low
voltage, battery failure.
Electromagnetic Compatibility
Immunity Conforms to EN50130-4.
Emissions Conforms to EN61000-6-3.
Outputs
O/P 1 - 4 Open collector transistor,
+12VDC when inactive, 0V
when active. 500mA max.
See page 37 for programming
details.
LS (loudspeaker) Min impedance 16 Ohm,
current consumption from
12VAux = 280mA in alarm.