Programming i-on16
Page 40
them). The exit time can take any value between 10s and
120s.
Entry Time
This option controls the Entry Time for both Full and Part
Set. The time can take any value between 10s and 120s.
Part Set Exit Mode
You can select an exit mode for part set that is different
from that used during full setting. Page 39 lists the exit
modes available.
Note: If you wish to use Final Door Set exit mode when
part setting then:
1. Make sure that you include a zone with the Final
Exit type as one of the part set zones.
2. Make sure you select “Final Door” in Part Set Final
Exit As (see below).
3. Remember that for Part Set to work you must
have at least one zone with the attribute Part Set =
“Yes”, see page 34 .
Pt. Set Final Exit
This option controls how the system will treat Final Exit
zones in Part set. When the option is set to Final Door
any Final Exit zones with the part set attribute will
continue to act as Final Exit zones during part set. When
the option is set to Normal Alarm any Final Exit zones
included in the part set attribute will act as Normal Alarm
zones during part set.
Pt .Set Entry Route As
This option controls how the system treats Entry Route
zones during part set. When the option is set to Entry
Route all Entry Route zones with the part set attribute will
continue to act as Entry Routes during part set. When the
option is set to Final Exit any Entry Route zones with the
part set attribute will act as Final Exit zones during part
set.