i-on16 Programming
Page 31
You have the choice of deleting the detector ID or of
defaulting the zone. Press u or n to see each of these
choices.
If you select “Delete Detector ID” then the control unit
“forgets” the ID of the detector, but leaves any zone
programming in place.
If you select “Default zone” then the control unit “forgets”
the ID of the Detector and sets all the zone programming
back to default values: Type = Not Used, no attributes.
To reinstate the detector you must teach the control unit
that detector's identity again.
Edit Zones
Once you have made the control unit learn radio
detectors then you can program each zone's behaviour.
Names, Type, Attributes
To change the name associated with a zone, its type, or
its attributes then select Detectors – Edit Zones .
The bottom line of the display starts at zone 1. Press u
or n to show the other zones. When you have found the
zone you wish to edit press >. The bottom line of the
display shows “Name”. Press u or n to see Type or
Attributes options for that zone. Press
> to select the
option you wish to change.
Changing Zone Names
When changing the zone name, key in the letters from
the keypad. Each number is associated with a range of
letters in the same way as on many mobile phones.
Figure 23 shows which letters appear on each key.
To delete characters press <. If you wish to move the
insertion point, then press u or n.
To change between capital and lower case letters press
#. The cursor changes to an underline when in lower case
mode.