Engineering Manual Engineer Menu 1-9
87
Latched code o/p – If the output is latched, the output activates when a user code is
entered, then deactivates when the user code is entered again. If the output is pulsed, the
output activates for the duration of the programmed pulse time, then deactivates.
17 – Latching 24hr / Nonlatching 24hr
Latching 24hr – 24 Hour zones (page 22) will cause an alarm when triggered and will be
re-armed only after entering a user code twice (once to silence the alarm, and once to
reset the alarm).
Nonlatching 24hr – 24 Hour zones will cause an alarm when triggered. On entering a user
code, the alarm is silenced. The zone is re-armed immediately after a user code is entered
to silence the alarm.
18 – Access code only / Access all codes
Access code only – Causes outputs that follow the Access Code or Access event (page 45
or 56) to activate only when a user code of type Access is entered.
Access all codes – Causes the outputs to activate when any user code is entered.
19 – NVM is Unlocked / NVM is Locked
NVM is Unlocked – The panel can be reset to its factory defaults by shorting the FACTORY
RESTART pins on the control panel PCB during power-up.
NVM is Locked – The panel cannot be reset to its factory default settings by shorting the
FACTORY RESTART pins. Keypads give a warning sound if the terminals are shorted.
)
If you select this option, it is imperative that you remember the engineer code .
20 – Unshunt, no exit / Unshunt & exit
Unshunt, no exit – Entering a Shunt user code (User option 8-1; see the
Manager's
Manual
) to reinstate zones does not start the exit procedure.
Unshunt & exit – Entering a Shunt user code to reinstate zones starts the exit procedure
for all the appropriate wards within the shunt group that are already set.
21 – Ignore errors / View exit errors
Ignore errors – When setting the system with one or more zones active (i.e. triggered), the
panel continues with the exit procedure, but displays the zones that are currently active. If
the zones are not cleared at the end of the exit procedure, the internal sounder sounds,
the external strobe flashes and the display shows an error.
View exit errors – When setting the system with one or more zones active, the panel
displays the zones that are currently active and does not allow the system to be set while
zones are active. After clearing the active zones, the panel prompts for confirmation to
continue with the exit procedure.
22 – Mimic, All times / Mimic, Set only
Mimic, All times – When using an output of type Mimic (page 58), the output mimics the
zone at all times.