Engineering Manual Engineer Menu 1-6
77
4 – Instant Set
Select this option if you want the ward to set quickly.
The ward sets 10 seconds after the user has chosen to set the ward (which should be
enough time for sensors to settle).
5 – Deferred Set
This is the same as Timed Exit, except that if any zones are activated during the exit
procedure, the Exit timer (page 60) is restarted.
6 – Lock Set
Select this option if you are using a lock switch connected to a Lock Set zone type to set
the alarm system. This enables the ward's Final Exit zone to be a normal Normal Alm zone
while the exit door is locked. See page 25 for further details.