Introduction Engineering Manual
12
Table 1. Voltage Drop
Current
Drawn
Cable Length (Standard 7/0.2 alarm cable)
10m 20m 30m 40m 50m 60m 70m 80m 90m 100m
60mA 0.10V 0.19V 0.29V 0.38V 0.48V 0.58V 0.67V 0.77V 0.86V 0.96V
80mA 0.13V 0.26V 0.38V 0.51V 0.64V 0.79V 0.90V 1.02V 1.15V 1.28V
100mA 0.16V 0.32V 0.48V 0.64V 0.80V 0.96V 1.12V 1.28V 1.44V 1.60V
120mA 0.19V 0.38V 0.58V 0.79V 0.96V 1.15V 1.34V 1.54V 1.74V 1.92V
140mA 0.22V 0.45V 0.67V 0.90V 1.12V 1.34V 1.57V 1.79V 2.02V 2.24V
160mA 0.26V 0.51V 0.77V 1.02V 1.28V 1.54V 1.79V 2.05V 2.30V 2.56V
180mA 0.29V 0.58V 0.86V 1.15V 1.44V 1.73V 2.02V 2.30V 2.59V 2.88V
200mA 0.32V 0.64V 0.96V 1.28V 1.60V 1.92V 2.24V 2.56V 2.88V 3.20V
220mA 0.35V 0.70V 1.06V 1.41V 1.76V 2.11V 2.46V 2.82V 3.17V 3.52V
240mA 0.38V 0.79V 1.15V 1.54V 1.92V 2.30V 2.69V 3.07V 3.46V 3.84V
260mA 0.42V 0.83V 1.25V 1.66V 2.08V 2.50V 2.91V 3.33V 3.74V 4.16V
280mA 0.45V 0.90V 1.34V 1.79V 2.24V 2.69V 3.14V 3.58V 4.03V 4.48V
300mA 0.48V 0.96V 1.44V 1.92V 2.40V 2.88V 3.36V 3.84V 4.32V 4.80V
320mA 0.51V 1.02V 1.55V 2.05V 2.56V 3.07V 3.58V 4.10V 4.61V 5.12V
340mA 0.54V 1.09V 1.63V 2.18V 2.72V 3.26V 3.81V 4.35V 4.90V 5.44V
360mA 0.58V 1.15V 1.73V 2.30V 2.88V 3.46V 4.03V 4.61V 5.18V 5.76V
380mA 0.61V 1.22V 1.82V 2.43V 3.04V 3.65V 4.26V 4.86V 5.47V 6.08V
400mA 0.64V 1.28V 1.92V 2.56V 3.20V 3.84V 4.48V 5.12V 5.76V 6.40V
420mA 0.67V 1.34V 2.02V 2.69V 3.36V 4.03V 4.70V 5.38V 6.05V 6.72V
440mA 0.70V 1.41V 2.11V 2.82V 3.52V 4.22V 4.93V 5.63V 6.34V 7.04V
460mA 0.74V 1.47V 2.21V 2.94V 3.68V 4.42V 5.15V 5.89V 6.62V 7.36V
480mA 0.79V 1.54V 2.30V 3.07V 3.84V 4.61V 5.38V 6.14V 6.91V 7.68V
500mA 0.80V 1.60V 2.40V 3.20V 4.00V 4.80V 5.60V 6.40V 7.20V 8.00V
520mA 0.83V 1.66V 2.50V 3.33V 4.16V 4.99V 5.82V 6.66V 7.49V 8.32V
540mA 0.86V 1.73V 2.59V 3.46V 4.32V 5.18V 6.05V 6.92V 7.78V 8.64V
560mA 0.90V 1.79V 2.69V 3.58V 4.48V 5.38V 6.27V 7.17V 8.06V 8.96V
580mA 0.93V 1.86V 2.78V 3.71V 4.64V 5.57V 6.50V 7.42V 8.35V 9.28V
600mA 0.96V 1.92V 2.88V 3.84V 4.80V 5.76V 6.72V 7.68V 8.64V 9.60V
Voltage Drop Example 1
Figure 5) shows two devices connected to the control unit. The first is 20m from the control unit
and has 60mA being taken from its auxiliary supply to power detectors. The second is 20m from
the first and also has 60mA being taken from its auxiliary supply to power detectors. The
example shows that the voltage levels at both nodes is acceptable. The voltage at each device is
as follows:
1. The total current being drawn at the first device = 120mA + 120mA = 240mA.
2. Voltage drop to the first device = 240mA @ 20m = 0.79V (see table).
3. Voltage at first device = control unit voltage - voltage drop = 13.60 -0.79 = 12.81V.
4. The total current being drawn at the second device = 120mA.
5. Voltage drop to the second device = 120mA @ 20m = 0.38 (see table).
6. Voltage at second node = first device voltage - voltage drop = 12.81 - 0.38 = 12.43V.
Voltage Drop Example 2
The second example in figure 5) shows what happens when a third device is connected 20
metres from the second.