Engineering Manual Engineer Menu 1-9
85
05 – On-Line (Keypad) Enabled / On-Line (Keypad) Disabled
On-Line Enabled – When using Downloader software, the On-Line Keypad feature in the
Downloader software is enabled.
On-Line Disabled – When using Downloader software, the On-Line Keypad feature is
disabled.
06 – Unset Ward First / Set Ward First
Unset Ward First – When the system is part set and a user code is entered, the “0=Uset
Wards” option is displayed first.
Set Ward First – When the system is part set and a user code is entered, the “0=Set
Selection” option is displayed first.
07 – Digi Normal / Digi Inverted
Digi Normal – The digital communicator outputs on the control panel switch from +12V to
0V when active (+ve removed).
Digi Inverted – The digital communicator outputs on the control panel switch from 0V to
+12V when active (+ve applied).
08 – Chime Audible / Chime Visible
Chime Audible – Zones that have a Chime Tone attribute (page 29) will only generate a
chime tone.
Chime Visible – Zones that have a Chime Tone attribute will generate a chime tone and
the keypads will display the zone that was triggered.
09 – Manual Omits / Automatic Omits
Manual Omits – Zones that have the Omittable attribute (page 28) can be omitted only
from User option 1-2 (see the
Manager's Manual
).
Automatic Omits – Zones with the Omittable attribute are automatically omitted if they
are active when the system is being set. This option is not relevant if the View Exit Errors
option is selected (page 87).
)
Do not use Automatic Omits if any ward is using a Deferred Set or Lock Set (page
77), otherwise the system will not set.
10 – Omit Tampers No / Omit Tampers Yes
Omit Tampers No – Omitting a zone using User option 1-2 (see the
Manager's Manual
)
will not also omit tamper faults from that zone.
Omit Tampers Yes – Omitting a zone using User option 1-2 also omits tamper faults from
that zone.
11 – Global Setting / Local Setting
Global Setting – Allows users to set a ward from any keypad, providing their user type
allows this and the ward has been allocated to the user (as specified in User option 2-4;
see the
Manager's Manual
). Also allows any telecommand to set a ward, providing the
ward has been allocated to the telecommand (see option 2-9).