Programming Reference - Testing 7510r
Page 74
control unit’s microphone. If necessary you can change
the volume of sound from the loudspeaker by selecting
Social Care Alarms, Set Volume
(see also “Controls and
Connectors” Figure 4 item 9 on page 4 and “Remote
Loudspeaker/Microphone on page 12).
Testing
If you think that part of the system is not working
correctly then you can use the Test option to test various
peripherals.
The Test option also lets you check the identity of
Telecommands, Pendants and Tags.
To start testing, make sure the system is idle then:
1. Enter the User Menu and select Test.
The display shows the Test menu.
2. Select the part of the system that you wish to test.
You can test each part listed in the Test menu as follows:
Siren
Press On/Off to turn the siren on and off again. The
display shows the word "On" when the siren operates.
Loudspeaker
Press On/Off to play a test message from the
loudspeaker. The display shows the word "Playing" when
you should be hearing the message.
Keypad
Press each key once. The display shows a character in
response. Press both dual keys together to test. Press OK
to end the test.
Walk test
The display shows a list of all the detectors installed on
the system. Walk round and trigger each detector. Every
time you trigger a detector the control unit gives a double
tone. The display shows an “A” if you trigger the Alarm
input and a “T” if you trigger the Tamper.
The top of the display shows the number of zones left to
test (both Alarm and Tamper).