7510r Programming Reference - Partitions
Page 37
Siren + Comms
Full alarm (communication and siren).
Part Set Exit Mode
You can select an exit mode for a part set partition that is
different from that used when the same partition is full
set. Page 35 lists the exit modes available.
Note: If you wish to use Final Door Set exit mode when
part setting a partition then:
1. Make sure that you include a zone with Final Exit
type in that partition.
2. Make sure you select “Final Door” in Part Set Final
Exit As (see below).
Part Set Final Exit As
This option controls how the system will treat Final Exit
zones in part set. When the option is set to Final Door
any Final Exit zones included in the partition will continue
to act as Final Exit zones during part set. When the
option is set to Normal Alarm any Final Exit zones
included in the partition will act as Normal Alarm zones
during part set.
Part Set Entry Route As
This option controls how the system treats Entry Route
zones during part set. When the option is set to Entry
Route all Entry Route zones included in the partition will
continue to act as Entry Routes during part set. When the
option is set to Final Exit any Entry Route zones included
in the partition will act as Final Exit zones during part set.
Strobe on Set (770r only)
When set to ON this option causes the control unit to
activate any associated 770r WAM programmed as a
sounder receiver (mode 4). The WAM operates its strobe
output when the partition sets.
Strobe on Unset (770r only)
When set to ON this option causes the control unit to
activate any associated 770r WAM programmed as a