Programming Reference - Reporting 7510r
Page 58
mode above it.) Use the table to decide which mode is
appropriate for the installation.
Note: The control unit delays reporting/logging either
mains loss, or leaving Installer Menu with mains loss,
by 15-22 minutes (chosen randomly). The control
unit delays reporting/logging either mains restore, or
leaving Installer Menu with mains restored, by 60-90
sec (chosen randomly).
Table 1. SIA Telegram Reports
BASIC
Event SIA Code CID
Code
ALARM CONFIRM BV 139
BURG BA 130
EXIT TIMEOUT EA -
FIRE FA 110
KEYPAD FIRE FA 110
KEYPAD MEDICAL MA 100
KEYPAD PA PA 120
KEYSWITCH SET CS 409
KEYSWITCH UNSET OS 409
MAN TRIGGER TEST REPORT RX 601
PANIC PA 120
PERIODIC TEST REPORT RP 602
SENSOR TAMPER TA 137
ZONE OMIT BB 573
SUMMARY (BASIC plus:)
Event SIA Code CID
Code
ALARM ABORT BC 406
ARM CL 401
DISARM OP 401
FIRE RESTORE FR 110‡
KEYPAD FIRE RESTORE FR 110‡
KEYPAD PANIC RESTORE PR 120‡
LID TAMPER TA 137
PANIC RESTORE PR 120‡
PART SET CL 401
PROG MODE END LS 628
PROG MODE START LB 627
RESET OR 305
SYSTEM TAMPER TA 137
TECHNICAL ALARM UA 150‡
TECHNICAL ALARM RESTORE UR 150
TAMPER USER CODE JA 461
Komentáře k této Příručce