M2000 Installation Instructions 13
Menu. If you lock the NVM DO NOT forget the
engineer passcode.
Serial Printer Connector
("19" in Figure 2.)
Serial printer
(e.g. DATAC )
RS232 Data
Connect to
control pa nel
Figure 17: Using a Printer
The SERIAL PRINTER connector enables a serial
(RS232) printer to be connected directly to the control
panel, such as a DATAC printer. Connection details are
shown in Figure 18.
The printer can, for example, be used to:
• Produce a hardcopy record of system
programming details.
• Print logged events. The system can be configured
to enable online printing, where logged events are
automatically printed as they occur.
The printer must be set up with the following
communication settings: 4800 baud, eight data bits,
one stop bit, one start bit, no parity and DTR normal.
0V
DTR
Tx
Pr i n t e r
Serial printer
connector on
control panel
Figure 18: Printer Connections
Output Module Connector
("20" in Figure 2.)
CPA6 output modules (now obsolete) can be
connected to the OUTPUT MODULE connector to
provide eight additional 100mA switched-negative
programmable outputs per module. The outputs can
be used to drive LEDs or other low-power devices (see
Figure 19).
Each output module is supplied with an interface lead,
which enables easy connection to the control panel (or
to an MSNode).
When the output module is connected to the control
panel, the outputs can be programmed to indicate
ward status or zone alarms.
For further details, please refer to the CPA6 Output
Module Installation Instructions.
PL1
1k Resistors
LEDs
1234 567
+12V IN
+12V OUT
+12V OU T
8
PL2
Connec t to plug
la b e lled OUTPUT
MODULE
100m max.
Figure 19: Output Module Connections
Engineer Keypad Connector
("21" in Figure 2.)
A keypad set with its ID selector switch set "ENG" can
be connected directly to the ENGINEERS KEYPAD
connector on the control panel, using the Engineer
Keypad Interface (EKI) lead. (Figure 20 provides
connection details.)
An engineer's keypad is intended to be temporary
connected to the control panel for system
configuration and testing at the control panel. The
keypad can be disconnected without causing an alarm.
Once a system has been set up, system configuration
should normally be carried out from a keypad
attached to Network 1 or 2.
The zone and output terminals on an engineer's
keypad cannot be used.
A
A
B
C
D
D
Ke y p a d
Fit
polarising
pin
Engineer's keypad
connector on
control panel
E
E
C
B
Figure 20: Engineer Keypad Connections
Serial Connection to PC
("22" and "23" in Figure 2.)
Optionally, a local PC running the Menvier Downloader
software can be connected to the control panel for
system configuration and data uploading. The PC can
connect to the panel's USB port ("22" in Figure 2) or
Serial RS232 port ("23" in Figure 2).
When using the RS232 port, use a null-modem serial
cable – wiring details are shown in Figure 21.