2. Programming Commands
Page 20 497096, issue 3
39: Level/Partition A Exit Mode
Use this command to select the exit mode for Full Set or Partition A. The
keypads give a double "beep" confirmation tone at the end of all setting
modes, including Silent Set. The default is option 0, Timed.
In a single system, the options are:
Option
0 Timed. Use this option if the system sets after an exit time selected
using Command 44. If an Exit Terminate button is fitted, the user may
use it to shorten the exit time.
1 Terminated. Use this option if the user completes setting the system
by pushing an Exit Terminate button connected to a keypad. The exit
time is infinite in this option. The system sets 7–12 seconds after the
completed action; the delay is set with Command 182 (see page 63).
2 Final Door Set. Use this option to complete setting of the system by
closing a door fitted with a Final Exit zone detector. The exit time is
infinite in this option. The system sets 7–12 seconds after the
completed action; the delay is set with Command 182 (see page 63).
3 Lock Set. To use this option, you must install a lock switch and
connect its contacts to the ET terminals of a keypad (refer to the 9x5x
Installation Guide). This facility is available on keypad software
version 1.4.2 onwards. See the notes below for more information.
In a partitioned system, the options are:
Option
0 Timed. Use this option if the system sets after an exit time selected
using Command 44. If an Exit Terminate button is fitted, the user may
use it to shorten the exit time.
1 Terminated. Use this option if the user completes setting the system
by pushing an Exit Terminate button connected to a keypad. The exit
time is infinite in this option. The system sets 7–12 seconds after the
completed action; the delay is set with Command 182.
2 Final Door Set. Use this option to complete setting of the system by
closing a door fitted with a Final Exit zone detector. The exit time is
infinite in this option. The system sets 7–12 seconds after the
completed action; the delay is set with Command 182.
3 Instant Set (no exit tone). Use this option to make the system set
without delay or exit tone.
4 Silent Set. Use this option to make the system set without an exit
tone. Use Command 44 to program the exit time.
5 Lock Set. To use this option, you must install a lock switch and
connect its contacts to the ET terminals of a keypad (refer to the 9x5x
Installation Guide). This facility is available on keypad software
version 1.4.2 onwards. See the notes below for more information.