Alert Messages
This section gives the meaning of the
messages that you might see when
resetting the system (page 14). Contact
your alarm company if there are problems
you cannot resolve.
ALARM 0005
08:13:45 01/01
A zone alarm has occurred. The display
shows the zone number, together with the
time and date.
PSTN LINE FAULT
12:00 Sun 01 JAN
The communication device fitted to your
alarm system is reporting a fault on the
telephone line. You may not be able to set
your system until you clear the fault.
AC Mains Fault
There is no mains power to the control unit
and the alarm system is running on its
standby battery. You may not be able to set
your system until the power is restored. If
the fault persists, the standby battery will
eventually run flat.
Battery Fault
The standby battery has developed a fault
or is disconnected. You may not be able to
set your system until the fault is cleared.
Contact your alarm company.
PANEL LID TAMPER
08:13:45 01/01
The lid of the control unit has been
removed. You may not be able to set your
system until the fault is cleared. Contact
your alarm company.
AUXILIARY X TAMP
12:00 Sun 01 JAN
The lid of an auxiliary device fitted to the
control unit is open. You may not be able to
set the system until the fault is cleared.
Contact your alarm company.