5. Testing
Telecmmd PA PA started from telecommand
Unn Change Unn User nn changed access code for user nn
Unn Delete Unn User nn deleted access code for user nn
Unn Off-Site Engineer exited programming mode
Unn On-Site Engineer entered programming mode
Bypass Supr. Znn Supervision on zone nn bypassed
Unn System Reset User nn reset system
Unn System Set User nn set system
Unn System UnSet User nn unset system
Unn Time/Date User nn changed the time and date
Unn Znn Omit User nn omitted zone nn
Unn Znn Unomit User nn un-omitted zone nn
Testing Outputs (Commands 91-95)
You may test parts of the system by entering commands at the keypad. To
carry out a test make sure the system is in programming mode and then key
in one of the following commands. Press to end each test:
91 To test output 1 (usually the external sounder/bell).
92 To test output 2 (usually the strobe output).
93 To test output 3.
94 To test the internal sounder output.
95 To test the keypad sounder.
Engineer Walk Test (Command 97)
Allows the engineer to test all devices on the system.
1. Enter programming mode.
2. Key in 97
The display shows:
3. Open and close each alarm and tamper contact in turn.
The system gives a chime tone each time you open and close a detec-
tor contact. The displays shows: "A:Zone:" and the zone number of
every detector you have tested (note that the display shows each zone
number for one second, in sequence). If you also test the tampers on
each zone the display shows the letter "T" against each zone number.
4. Press to stop the walk test.
Note that the Engineer's walk test allows you to test all zones including PA
zones, zone tampers, and control unit and bell tampers. The user's walk test
does not allow you to test PA, Fire, 24Hr, Technical zones, or tampers.